PowerLINE Contactors
1-800-633-0405
g

cPowerLINE IEC contactors

With the advent of automation, use of multi/complex drives brought into the fore the use of Electro-mechanical switching device namely, the contactor. Prices start at $15.00 for a 4Kw Contactor

Our PowerLINE motor controls by AutomationDirect line of load switching devices gives you high quality contactors with the same features as the big brands, but at prices that are hard to believe!

Features:

  • Common side & front mounted auxiliary contact blocks upto 70A.
  • Diagonal or top, wiring options for coils upto 70A contactor.
  • Front access to contacts
  • Shrouded terminals for safety sgainst accidental touch
  • DIN rail mounting upto 140 A Contactors
  • Wide range of accessories which includes add on Auxillary COntact Block - front & side mounted, Electronic Star Delta Timer, Surge Suppressors, Wide band Coils, Mechanical Interlock. Click here to Download Brochure
  • Specifications: IEC:947-4, IS:13947-4
Frame
Size (mm)
Current Rating
AC-3 Duty
(Amps)
Power Rating
(KW)
1
45
9, 12, 16
4, 5.5, 7.5
2
45
18, 25, 32
9, 11, 15
3
70
40, 50, 70, 80
22, 25, 37, 40
4
118
95, 125, 140, 170
45, 63, 75, 90
6
163
250, 325, 400
140, 185, 220

 

Thermal Overload Relay

o

A wide range of bimetal thermal overload relays are offered for close protection of motors & other inductive loads against overload, single phasing &
unbalanced system voltages.

Type :

  • Auto reset
  • Auto / Manual reset

Range :

  • Contactor Mounting - 0.16A to 80A in 26 direct reading version.
  • Individual Mounting - 0.16A to 34A in 18 direct reading version.
  • CT Operated - 24A to 400A in 8 current transformer operated version.

Specification :
Conforms to IEC:60947-1&4 / IS:13947-1&4

Features :

  • Protection against overload & single phasing

  • Manual or auto reset facility

  • Ambient temperature compensated

  • Off & test mode facility in certain sizes

  • Individual or DIN Rail mounting facility

  • Matching to the contactor size up to 80A
PowerLINE Motor Controls: Overloads

Manual Starters / Protectors

GH Series motor starter/protectors (MSP) offer all-in-one motor protection for many applications.
Contained in one unit is motor overload protection, instantaneous short circuit trip, phase loss protection and ON/ OFF switching with lockout/ tagout capability.
Add an optional shunt trip for remote tripping of the MSP, or an optional undervoltage release for tripping the MSP when an undervoltage situation occurs.
Auxiliary contact blocks are also available for signaling pilot lights, PLC inputs, control circuits, etc.
Add a GH Series contactor for a complete remote motor control solution.

NOTE: Contactors and motor starter/protectors (MSPs) are sold separately.

Features :

  • Push on / push off manual control disconnects power from motor
  • Electromagnetic short circuit protection eliminates the need for separate breakers or fuses.
  • Overload heater strips protect the motor from sustained overload conditions.
  • Phase loss detection trips when a phase is lost to protect the motor
  • Options include undervoltage trip, remote shunt trip, and aux. contacts

 Miniture Circuit BreakerS(MCBs)

cb

Specifications: IEC:60898-1995/IS-8828-1996

Range:
6A to 63A in 'B' Curve
0.5A to 63A in 'C' Curve
0.5A to 63A in 'D' Curve*
0.5A to 63A for DC Application.

Execution:
Single Pole
Single Pole & Neutral
Double Pole
Three Pole
Three Pole & Neutral
Four Pole


Features:

  • Uniform 10KA breaking capacity for 'B' and 'C' Curve
  • Low power consumption, thus cost effective & energy saving
  • Suitable for DC and for a wide frequency range of 50Hz - 400Hz application
  • "Finger Safe" terminals - IP 20 degree of protection
  • Dual Termination facility.
  • 15 Plate Arc Chute for effective arc quenching.
  • Silver Graphite contacts for enhanced life
  • Accessories
    --- Auxiliary Switch
    --- Shunt Trip

 

 


The flow of current through electrical facilities always involves risks. Poorly insulated equipment, faulty wires and incorrect use of an electrical devise cause
currents to flow through the wrong path (i.e., through the insulation) to the earth. This current is called ‘Leakage Current’.

Range
16A to 63A

Sensitivity
30mA, 100mA, 300mA, 500mA

Execution
Double Pole, Four Pole

Specification
IEC 61008 - 1 / IS 12640 - 1: 2000

Features

  • Simple and Robust operating mechanism.
  • Rotary handle with ON/Off indication
  • Dual termination for Bus Bar as well as cable connection
  • Advance Neautral
  • Test Button for regular inspection

.


Residual Current Circuit Breakers (RCCBs)

rccb

 

n
b

The latest & most innovative addition to Havell's product range; RCBO provides human safety that is protection against electrical shock, short circuit,
fire hazards & indirect contacts. It also provides Protection to all types of electrical gadget/installation from overload hazards

Range
16A, 20A,25A, 32A, 40A, 50A

Execution
Double Pole

Specificatio
IS 12640 (Part 2) : 2001 & IEC 61009-2-1

RCBO
rb
n