Over more than two decades, DYMEC-DynaStar has pioneered unique utility and industrial-grade electric to fiber-optic solutions. Our family of substation hardened Optical Ethernet Hubs, Optical Ethernet Data Links, Optical Serial Data Links, Optical Link/Repeaters and Optical Stars are designed specifically for power utilities and industrial communication applications where signal integrity, reliability and overall costs are important considerations.

Our Links, Link/Repeaters and Optical Stars is ruggedized to meet or exceed the most stringent requirements. We build the world's only truly substation-hardened Fiber-Optic Data Links by:

  • Using a minimum 20-year design life criteria based on continuous operation in temperature extremes from -40° to +85°C.
  • Conformal coating of internal circuit boards makes them highly resistant to moisture and contamination.
  • Packaging our Data Links and Link/Repeaters in rugged, industrial-quality Galvaneal shells.
  • Building models for either a low voltage platform or a platform with power inputs Surge Withstand Protected to IEC 61000-4-4, 61000-4-5 Standard and ANSE/IEEE C37.90 that can be directly connected to power station sources.
  • The ability to withstand EMI and RFI present in Substations.

All DYMEC-DynaStar Links, Link/Repeaters, and Optical Stars are designed to be passive to software protocols. Multimode devices operate on 850 nanometer wavelength, and single-mode units operate on 1300 nanometer wavelength light. All these features have made DYMEC-DynaStar digital-to-optical-fiber products The Industry Standard.


SubStation Hardened RS232 Serial Copper to Fiber Link/Repeaters

For Reliable Substation Communications

View Product Brochure

View User Manual   

Technical Description

Dymec-DynaStar models 5843 and 5844 are hardened fiber optic Link/Repeaters that convert RS232 or TTL level copper to amplitude based fiber output. Supports data rates from dc to 250k bps, DCE or DTE port configuration and a diagnostic/test mode that allows testing of the copper and fiber connections before the connected IED is active in the network.

By simply setting a few switches, the DYMEC-DynaStar 5843 and 5844 Link/Repeaters can be configured for point-to-point, star, optical bus, or loop networks, and permit quick, easy connection of devices. For example, an extensive multi-drop network -- where two or more intelligent electrical devices are connected and communicating -- can be constructed simply by connecting the devices through Link/Repeaters.

DYMEC-DynaStar 5843 and 5844 Link/Repeaters may optically connect devices of different formats, eliminating the need for format converters. For example, an RS232 IED may be connected to a model 5844 which is optically connected to a model 5846, which, in turn, can communicate electrically to its IED electrically in EIA 485.

Features and Benefits

  • Single Channel RS232 or TTL Logic Levels
  • Powered from Station Battery Bus to C37.90 or 12 Vdc
  • Operates reliably at temperatures of -40°C to 85°C with no fans.
  • Extended distances of 6 km over Multimode fiber and 30 km over Single-mode fiber.
  • Multiple Mounting choices with built-in mounting brackets and optional mounting shelf
  • Packaged in rugged, industrial-quality Galvaneal and powder coated shells
  • 4 Diagnostic LEDs for easier debug of installation
  • Conformal coated PC Boards
  • Compatible with all earlier 5843/5844 versions of Dymec Link/Repeaters
  • 5-year warranty

Ordering Information

Model Input Fiber Type Input Power Rating
5843HRT RS232/TTL Multimode 9 - 15 Vdc
5844HRT-H RS232/TTL Multimode 90-250 Vdc/ 90-250 Vac
5844HRT-L RS232/TTL Multimode 24 to 48 Vdc
5843SHRT RS232/TTL Single-Mode 9 - 15 Vdc
5844SHRT-H RS232/TTL Single-Mode 90-250 Vdc/ 90-250 Vac
5844SHRT-L RS232/TTL Single-Mode 24 to 48 Vdc
 
ACC-LCS Link Cantilever Mounting Bracket
ACC-CBL1 DB9 Male/Tinned Lead 10 Foot Cable/Pigtail

Specifications

Optical Parameters @ Maximum Temp Multimode Single-Mode
Optical Budget Typical 19.5 dB 19 dB
Output power Typical -10.5 dBm peak -14.5 dBm peak
Receiver Sensitivity Typical -30 dBm peak -33.4 dBm peak
  (62.5µ/125 Multimode) (9µ/125 Single-mode)
Wavelength 850nm 1310nm
Connector Type ST
Compatible Fiber Type Multimode (50-200µm) Single-Mode (9-13µm)
Configuration (Switches) DTE/DCE
  AC/DC Coupled
  Link/Repeat
  Pin 8 Drive Current
  Pin 6 +5 Vdc (DSR or CTS pull up)
  Diagnostic Mode
Data Rate DC to 250K bps
Data Transmission Asynchronous, simplex or Full Duplex
Transmission Distance up to 5000 meters
(62.5µ/125 Cable@3dB/km)
up to 30K meters
(9µ/125 Cable@0.5dB/km)
Bit Error Rate 10-E9 Max.
Point to Point Latency 4 µsec Max
Repeat Latency 400 nsec Max
Electrical Parameters
Inputs
I/O Data Format EIA RS232; CCITT v24
Data Connector 9 pin D-Type Female
Input Impedance >3000Ohms
Input Voltage +/- 30 Volts Max
Outputs
Output Impedance >300 Ohms
Driver Output +/- 5 V min into 3000 Ohms
Pin 8 Output 0 to 5V
67 or 207 Ohm Source Impedance
Ambient Temperature
Operating Temperatures -40 to +85 C -40 to +70 C
Storage Temperature -40 to +85 C
Power Required
5844 4.0 Watts 5.5 Watts
  35 mA @ 90-250 V 50 mA @ 90-250 V
  250 mA @ 18-60 V 340 mA @ 18-60 V
5843 3.0 Watts 4.1 Watts
  250mA @ 12Vdc 340mA @ 12Vdc
Power Dissipation BTU/H
5844 10.9 BTU 12.3 BTU
5843 8.2 BTU 10.2 BTU
Physical Parameters
Weight
5844 17 Ozs. 17 Ozs.
5843 9 Ozs. 9 Ozs.
Dimensions Inches
5844 4.1W X 5.1L X 1.3H
5843 2.0W X 5.1L X 1.3H
Indicators Power
  Transmit Fiber
  Transmit Electrical
  Receive Fiber
  Receive Electrical
Specifications Subject to Change Without Notice

Industrial Hardened EIA 422/485 Serial Fiber Link/Repeaters

For Reliable Utility and Industrial Communications

View Product Brochure

View User Manual   

Technical Description

DYMEC-DynaStar model 5845 and 5846 Serial Fiber Links are hardened media converters and link/repeaters for EIA 422 and 485 data connections. The 5845/5846 Links provide reliable serial data connectivity over fiber optic facilities in harsh environments where immunity and signal isolation are critical. Optical connectivity provides for flexible, extended-distance connectivity, increases operational safety, reduces equipment outages due to electrical surges and improves signal quality and network performance.

5845/5846 Links support signal rates from DC to 2 Mbps and operate either full- or half-duplex over single- or multi-mode fiber. Links are easily field-configurable for point-to-point, master/slave, loop, bus or star topologies. Logic Inversion enables interoperability with Model 5843/5844 links to mix RS232 and EIA 422/485 end devices in the same local networking configurations. The 5845/5846 also connect optically with the DYMEC-DynaStar Network Integration System and Optical Star products to cost-effectively create highly scaleable data networks with minimum electrical signal exposure.

DYMEC-DynaStar Links are substation-hardened to C37.90 and IEEE P1316 specifications. They operate in an extended temperature range and take DC power directly from station battery. Flexible mounting options, diagnostic LEDs and integrated optical and electrical signal test features make turning up a Link network simple.

Features and Benefits

  • Signal protection and electrical isolation for data connections and devices
  • Hardened to C.37.90, IEEE P1316
  • Operates –40° to +85°C with no fans
  • Powered from Station Battery Bus to C37.90 or 12 Vdc
  • Point-to-point, master/slave, loop, star and bus topologies
  • Extends 5 km over multi-mode fiber and 30 km over single-mode fiber
  • Interoperates with other DYMEC-DynaStar products, including RS232 links
  • Diagnostic LEDs and test features for easy debug of installation
  • Built-in mounting brackets and optional mounting shelf
  • Rugged, industrial quality Galva Neal and powder coated shells
  • Conformal coated PC Boards
  • 5-year warranty

Ordering Information

Model Input Fiber Type Input Power Rating
5845HRT EIA 422/485 Multimode 9 - 15 Vdc
5846HRT-H EIA 422/485 Multimode 90-250 Vdc/ 90-250 Vac
5846HRT-L EIA 422/485 Multimode 24 to 48 Vdc
5845SHRT EIA 422/485 Single-Mode 9 - 15 Vdc
5846SHRT-H EIA 422/485 Single-Mode 90-250 Vdc/ 90-250 Vac
5846SHRT-L EIA 422/485 Single-Mode 24 to 48 Vdc
 
ACC-LCS Link Cantilever Mounting Bracket
ACC-CBL1 DB9 Male/Tinned Lead 10 Foot Cable/Pigtail

Specifications

Optical Parameters @ Maximum Temp Multimode Single-Mode
Optical Budget Typical 19.5 dB 19 dB
Output power Typical -10.5 dBm peak -14.5 dBm peak
Receiver Sensitivity Typical -30 dBm peak -33.5 dBm peak
  (62.5µ/125 Multimode) (9µ/125 Single-mode)
Wavelength 850nm 1310nm
Connector Type ST
Compatible Fiber Type Multimode (50-200µm) Single-Mode (9-13µm)
Configuration (Switches) Half/Full Duplex
  Data Inversion Mode
  AC/DC Coupled
  Link/Repeat
  Bias Resistors In/Out
  Enable Holdover Timing
  Diagnostic Mode
Data Rate DC to 200 Mbps
Data Transmission Asynchronous, simplex or Full Duplex
Transmission Distance up to 5000 meters
(62.5µ/125 Cable@3dB/km)
up to 30K meters
(9µ/125 Cable@0.5dB/km)
Bit Error Rate 10-E9 Max.
Point to Point Latency 500 nsec Max
Repeat Latency 400 nsec Max
Electrical Parameters
Inputs
I/O Data Format EIA 422; EIA 485
Data Connector 9 pin D-Type Female
Input Impedance 750 Ohms
Input Voltage -7 V to +12 V max on each line; +/- 6 V Max differential
Outputs
Output Impedance 250 Ohms
Driver Output 50 mA
Ambient Temperature
Operating Temperatures -40 to +85 C -40 to +70 C
Storage Temperature -40 to +85 C
Power Required
5846 6.0 Watts 8.0 Watts
  45 mA @ 90-250 V 60 mA @ 90-250 V
  250 mA @ 18-60 V 340 mA @ 18-60 V
5845 3.0 Watts 4.0 Watts
  250mA @ 12Vdc 340mA @ 12Vdc
Power Dissipation BTU/H
5846 20 BTU 27 BTU
5845 10 BTU 14 BTU
Physical Parameters
Weight
5846 17 Ozs. 17 Ozs.
5845 9 Ozs. 9 Ozs.
Dimensions Inches
5846 4.1W X 5.1L X 1.3H
5845 2.0W X 5.1L X 1.3H
Indicators Power
  Transmit Fiber
  Transmit Electrical
  Receive Fiber
  Receive Electrical
Specifications Subject to Change Without Notice