All-in-One
PLC with Amazing Capabilities!
Feature
Summary
- All in One PLC
- AC power supply or DC power supply
- User program area: 7680 word / Data Registers:
7.3k word
- Instruction execution time: 0.7
- Scan time: 1.5ms/1k word (with standard
instructions)
- High-speed Input 4 pts / High-speed Output
2 pts
- 2 Communication Ports
- 8ch PID Control
- I/O Functions: 20 Inputs and 16 Outputs
- Real Time Clock / Calendar
- Battery back up (optional)
- 4 Modular Expansion Slots (Compatible
with DL05 series I/O option cards)
- Expansion I/O Card (optional)
- LCD Monitor (optional)
- Compliant with DeviceNet and CUnet (Need
combination use of Option modules)
The
function which can be operated by LCD
1) Default screen
2) Menu screen:
kkkkkkkkPLC Information, System
configuration, Monitor, Calendar R/W,
kkkkkkkkPassword operation,Error history
read, LCD Test & Set.
3) Diagnostic error display
4) LCD instruction display |
|
Communication
Ports & Switches
Port 1
6P female modular connector RS232C
DirectNet (Slave) , K-sequence (Slave) , MODBUS (Slave) protocol (Automatic
select) Port 1 supports programming and operator interface connectivity,
while Port 2 can be used for RS-232/422/485 networking, or ASCII in/out
to other devices.
Port 2
15Pin female D type Connector (High density) RS-232C / 422 / 485
DirectNet (master/slave), K-sequence (slave), MODBUS (master/slave),
Non-sequence (ASCII In/Out, PRINT Instruction), Koyo Remote I/O This
allows connectivity to an operator interface and networking to an AC drive
or another PLC, all at the same time. Supports industry- standard Modbus
RTU protocol (both master and slave on Port 2 up to 38.4 K).
Mode SW. (3mode)
RUN / TERM / STOP
Expansion I/O Card (optional)
Expansion I/O Card enables to connect up to 100 discrete I/O points
Available in eight models: The DL06
PLC line includes eight models to choose from in both AC and DC powered
models. With its wide range of power supply capabilities (100-240 VAC
and 12-24 VDC), the DL06 won't need an additional transformer in most
applications. This makes the DL06 a great fit for even high voltage, 220-240
VAC applications or remote 12 VDC applications, and everything in between.
Eight PID loops with autotune: The
DL06 supports its great analog capabilities with PID and floating point
math at no additional charge.
High-speed counting: The DL06 includes
built-in configurable motion control I/O. With the DL06, there is no need
to purchase a separate motion controller or programmable limit switch
(PLS) if your application only includes one simple motion requirement.
Option
modules:

- Analog
input module F0-04AD-1
- Four 12-bit, 0-20ma or 4-20ma input channels
- Removable terminal block
- Use signals for monitoring and control
applications, or as the process variable for the fill-in-the-blank PID
loop function in any model DL05 (Version 3.0C of DirectSoft required)
Analog input/output module F0-2AD2DA-2
- Two 12-bit, 0-5 VDC or 0-10 VDC input
channels and two 12-bit, 0-5 VDC or 0-10 VDC output channels
- Removable terminal block
- Use signals for monitoring and control
applications, or as the process or output variable for the fill-in-the-blank
PID loop function in any model DL05 (Version 3.0C of DirectSoft required)
Analog input/output module F0-4AD2DA-2
- Four 12-bit, 0-5 VDC or 0-10 VDC input
channels and two 12-bit, 0-5 VDC or 0-10 VDC output channels
- Removable terminal block
- Use signals for monitoring and control
applications, or as the process or output variable for the fill-in-the-blank
PID loop function in any model DL05 (Version 3.0C of DirectSoft required)
- RTD Input Module F0-04RTD
4 channel RTD Input Module, 0.1 degrees C resolution, supports: Pt100,
jPT100, Pt1000, Cu10, Cu25, Ni120
- Thermocouple Input Module F0-04THM
4 CHANNEL THERMOCOUPLE OR 16-BIT MV INPUT
DeviceNet slave module D0-DEVNETS
- DL06 becomes a "smart node" on a DeviceNet
network using this new communications option module
- Adds low-cost and small-footprint discrete
I/O to an application requiring Devicenet bus interface
- CUnet A Whole New Way of Networking
D0-HSIO
- The chipset,"MKY40",has own communication
protocol built-in.
- Up to 64 stations,4096 I/O points per
1 Network.
- Super high-speed data communication.
- The CUnet does not require master/slave
arrangement.
- Supporting multi-drop network connection.
- Mail function can be used for the data
transmission to communicate more than 4096 I/O points.
- No programming is necessary for communication
module setting.(Only SW settings)
- Each shared data will allocated on link
relay (GI/GQ),so you won't be conscious of distinguishing I/O points
between stations while programming.
- Mail function is simply controlled by
four instructions.
- CUnet modules are available for all
DL-05, DL-06,and Terminator I/O.

Ethernet Communication Module H0-ECOM
- Ethernet Communication Module, master/slave
on an Ethernet 10Base-T network at 10 Megabaud, cable not included.
Uses standard RJ45 modular connectors and supports UDP/IP and IPX protocols.
Applications for the H0-ECOM include online programming of DL05/06 PLCs
using DirectSOFT32 over Ethernet, and simultaneous data serving to HMI/SCADA
and information systems using OPC over Ethernet. The H0-ECOM can accept
a standard IP address and subnet mask to be used in conjunction with
standard routers and switches.
-
Use the DL06 to:
- Build a micro process monitor/controller
using the PID function and analog input option module.
- Add a local operator interface to set
and view parameters.
- Network distributed I/O nodes with local
intelligence that can also communicate globally.
- Use 10-30VDC powered units in remote
locations for data monitoring and control.
NEW! D0-DCM Data Communications
Module
The D0-DCM Data Communications
Module offers two communication ports for a variety of simultaneous communications
possibilities. It is primarily used for three reasons: Extra communications
ports to connect a PC, operator interface, etc. Network interface to DirectNET
Network interface to a MODBUS® network using the RTU protocol The top
RJ12 RS232 port can be used for PLC programming, connection to an OI panel
or as a single DirectNet or K-sequence slave.
The 15-pin front port can
be used for either RS232/422/485 communications and supports the following
protocols: K-sequence slave, DirectNet master/slave, MODBUS RTU master/slave
and ASCII input or output (ASCII/PRINT instructions). Extra communication
ports If additional communication ports are needed, they can easily be
added by installing DCM modules. This allows additional connections of
devices, such as operator interfaces, PCs, etc. Since the DCM does not
require any programming, you can set the DCM communication parameters
using DirectSOFT32, connect the cables, and start transferring data. Make
sure the connected device has a DL05/06 compatible driver. DirectNet network
interface
The DCM can be used as a
network interface for applications requiring data to be shared between
PLCs, or between PLCs and an intelligent device such as a host PC.
The DCM connects easily
to DirectNET. This network allows you to upload or download virtually
any type of system data including Timer/Counter data, I/O information,
and V-memory information from any DirectLOGIC or compatible PLC.
Port 2 on the DCM
allows the DL05/06 to function as a DirectNET network master or slave.
MODBUS RTU interface The DCM can be used as a master or slave station
interface to connect your DL05/06 system to a MODBUS® network using the
MODBUS RTU protocol. The DL06 CPU supports the MRX/MWX MODBUS network
instructions. These instructions allow you to enter native MODBUS addressing
in your ladder program with no need to perform octal to decimal conversions.
Connect directly to common
ASCII devices Port 2 on the DCM supports several ASCII input/output capabilities
when used with the DL06 PLC including raw ASCII strings and embedded ASCII
via a supported protocol (MODBUS, DirectNet, K-Sequence) from an external
HMI or similiar master. Interface your ASCII devices, such as barcode
readers, weigh scales or embedded controllers to the DL06/DCM/port2 using
our "AIN" (ASCII input) instruction. There are also instructions that
support ASCII output for printers, labelers or other compatible serial
devices.
Communication Ports & Switches:
Port 1: 6P female modular connector
RS232C DirectNet (Slave) , K-sequence (Slave) , MODBUS (Slave) protocol
(Automatic select)
Port 2: 15Pin female D type Connector
(High density) RS-232C / 422 / 485 DirectNet (master/slave), K-sequence
(slave), MODBUS (master/slave), Non-sequence (ASCII In/Out, PRINT Instruction),
Koyo Remote I/O
Mode SW:. (3mode) RUN / TERM / STOP
Expansion I/O Card (optional) Expansion I/O Card enables to connect up
to 100 discrete I/O points Port 1 Port 2 Expansion I/O Card (optional)
Dimensions:

Models:
|